Fan Blade Damage Inspection & Blend-Out Repair Procedure
Identify the damaged area on the fan blade and record the blade number.
Determine the specific area/zone of the fan blade and refer to the AMM for allowable limits applicable to that region.
Use the Go/No-Go gauge to perform an initial assessment once the area or zone is identified.
Position the Go/No-Go gauge along the leading edge (L.E.) or trailing edge (T.E.) of the fan blade.
Align the gauge centerline with the centerline of the damage.
Ensure the gauge area/zone markings correspond to AMM limit references.
Compare the measured damage against AMM allowable limits.
Within a repairable zone — proceed to Step 4.2.
Outside allowable limits (non-repairable condition) — immediate replacement is necessary.
If the damage exceeds allowable limits, replace the affected fan blade.
If the damage is within a repairable zone, proceed with blend-out in accordance with the AMM.
Refer to the AMM for maximum allowable blend-out limits.
Select the appropriate blend tooling guide for the affected area/zone.
Position the blend tooling guide centered over the damaged area of the fan blade.
Once the blend tooling guide fully covers the damage, mark the area to be blended.
Align the inner edge of the blend tooling guide with the leading edge (L.E.) or trailing edge (T.E.) of the fan blade as applicable.
Perform the blend-out procedure in accordance with the applicable AMM. All required consumables are included in the kit to facilitate an expeditious repair process.