Fan Blade Damage Inspection & Blend-Out Procedure
AVIAFRAME TECH — FIELD PROCEDURE

Fan Blade Damage Inspection & Blend-Out Repair Procedure

Kit ref: FOD-INSP-01 Patent pending — US 64/135,647
What's in this kit
Go/No-Go gauge (depth & length scale)
Blend tooling marking blocks — Areas A–D
Midspan marking block
Fine & coarse hand files
Abrasive finishing sticks
Sandpaper sheet
Sharpie marker
Inspection light / loupe
1
Preparation
1.1

Identify the damaged area on the fan blade and record the blade number.

1.2

Determine the specific area/zone of the fan blade and refer to the AMM for allowable limits applicable to that region.

2
Initial Damage Assessment
See Fig. 1
2.1

Use the Go/No-Go gauge to perform an initial assessment once the area or zone is identified.

2.2

Position the Go/No-Go gauge along the leading edge (L.E.) or trailing edge (T.E.) of the fan blade.

2.3

Align the gauge centerline with the centerline of the damage.

2.4

Ensure the gauge area/zone markings correspond to AMM limit references.

Figure 1 — Fan Blade Tooling: Go/No-Go gauge alignment
Figure 1 — Fan Blade Tooling
3
Damage Evaluation
3.1

Compare the measured damage against AMM allowable limits.

Within a repairable zone — proceed to Step 4.2.

Outside allowable limits (non-repairable condition) — immediate replacement is necessary.

4
Repair Decision
4.1

If the damage exceeds allowable limits, replace the affected fan blade.

4.2

If the damage is within a repairable zone, proceed with blend-out in accordance with the AMM.

5
Blend Preparation
See Fig. 2
5.1

Refer to the AMM for maximum allowable blend-out limits.

5.2

Select the appropriate blend tooling guide for the affected area/zone.

5.3

Position the blend tooling guide centered over the damaged area of the fan blade.

Figure 2 — Blend Tooling Guide: template selection and marking
Figure 2 — Blend Tooling Guide
6
Marking & Alignment
6.1

Once the blend tooling guide fully covers the damage, mark the area to be blended.

6.2

Align the inner edge of the blend tooling guide with the leading edge (L.E.) or trailing edge (T.E.) of the fan blade as applicable.

7
Blend-Out Execution
7.1

Perform the blend-out procedure in accordance with the applicable AMM. All required consumables are included in the kit to facilitate an expeditious repair process.

Reference only. Gauge zone markings and blend-out limits shown are for illustration. Always verify allowable damage and blend-out limits against the current Aircraft Maintenance Manual (AMM) for the specific engine and blade part number before performing any repair or replacement decision.
AVIAFRAME TECH LLC
Austin, Texas  ·  Fan Blade Damage Assessment & Blend-Out Marking System